• PERKINS
  • BAUDOUIN
  • MITSUBISHI
  • FPT IVECO
  • SCANIA
  • YANGDONG
  • SDEC
  • KOFO
Download PDF
{PAGENO}
Emsa reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice.
ETW DT EM 1100
EMSA Generator - PHP first page

ETW DT EM 1100

Deutz Series
Twin Diesel Generator Sets

STAND BY kVA 1100
kW 880
PRIME kVA 1000
kW 800
1100 kVA Deutz, Emsa EGK315-400N, 50 hz
Water Cooled
50 hz
Easy maintenance
Modular type sound-proof canopy
3 phase
Diesel
Warning system for decreasing fuel with electronic fuel level sender
Remote control system

Standby Rating for a standby engine should be sized for a maximum of 70% average load factor and roughly 200 hours per year. Stand­by power ratings should never be applied except in true emergency outage situations. With standby rated generators there is no overload capability built into the units.

Prime Power is the maximum power accessible at the variable load for an unlimited number of hours per year in a variable load setting. It is not advisable that the variable load exceed 70% average of the prime power rating during any operational period. If the engine is run­ning at 100% prime power, yearly hours should not exceed 500. Overload situations should be avoided however a 10% overload capability is available for a 1 hour period within a 12 hour cycle of operation.

Continuous Power is used in applications where suppliying power is at a constant %100 load for an unlimited number of hours each year. Continuous power rated units are most widely used in applications where the power grid is unreachable.

QUALITY STANDARDS

Our generators are manufactured in compliance with VDE 0530, BSE 4999 BS5000, IEC 34, EN12601; EN60204-1; TS ISO 8528-1 … -13; EN12100-1; EN12100-2; EN61000-6-4; EN61000-6-2; EN61000-4-11; EN61000-4-6; EN61000-4-5; EN61000-4-2; EN55011; EN55016-2-1; EN55016-2-3; EN61000-3-2; EN61000-3-3; EN55014-1; EN61000-6-2; EN61000-4-3; EN61000-4-4; EN61000-4-8; EN61000-4-11; TS EN ISO 3744; TS EN ISO 3746; TS EN 60034-1; TS EN 60034-22; TS EN ISO 3046; BS 5514; NEMA MG 21; IEC 60034, BS 4999/5000 and TS EN 60947-1..4 standards.

We have ISO 9001-2015, ISO 14001-2015, ISO 45001-2018 and ISO 1002-2006 management system certificates from Kiwa, an accredited independent quality organization.

Our generators up to 400 kw are manufactured in compliance with 2000/14/EC European noise emission directive and certified from Ente Certificazione Macchine.

We also have TS ISO 8528-4, TS ISO 8528-5, TS EN 13501-1+A1:2013 flame retardancy and TTS EN ISO 9227 certificates against anti-corrosion together with CE Declaration.

Engine Specifications

Engine Specifications

  • Deutz series heavy duty diesel engine
  • 4 CYCLE, WATER COOLING SYSTEM, TURBOCHARGED - INTERCOOLER INDUCTION
  • Electronic governor system
  • 12/24 volt self-starter and charger alternator
  • Changeable air, fuel and oil filter
  • Flexible fuel pipe
  • Oil discharge valve and extention pipe
  • Industrial type silencer, exhaust spiral or compensator
  • Maintenance free battery
  • Engine block water heater (in automatic models)
  • Diesel gen-set maintenance and operating instructions and electrical circuit diagram
MODEL BF8M1015C-LA G2
POWER STAND BY kW 440
PRIME kW 416
SPEED (rpm) 1500
CYCLE 4
DISPLACEMENT (lt) 15,874
NUMBER OF CYLINDERS 8 V
BORE AND STROKE 132 x 145
COMPRESSION RATIO 16.5 : 1
GOVERNOR TYPE Electronic
INDUCTION TURBOCHARGED - INTERCOOLER
COMBUSTION SYSTEM DIRECT
COOLING SYSTEM WATER
FUEL CONSUMPTION (lt/h) 100% OF PRIME POWER 94,03
75% OF PRIME POWER 70,53
50% OF PRIME POWER 47,02
TOTAL LUBRICATION SYSTEM CAPACITY (lt) 48
TOTAL COOLANT CAPACITY (lt) 87
Alternator Specifications

Alternator Specifications

  • Brushless, single bearing, flexible disc 4 poles alternator for harmonic failure
  • H type isolation class
  • IP 21-23 protection class
  • Self exciter
  • Electronic automatic voltage regulator
  • Stator 2/3 step for harmonic failure
  • The alternator windings are protected by insulating varnish against oil and acid
BRAND Emsa
MODEL EGK315-400N
FREQUENCY (HZ) 50
POWER (KVA) 550
DESIGN 4 pole, brushless
CONNECTION TYPE Star
VOLTAGE (V) 400
phase 3
A.V.R. KR440
VOLTAGE REGULATION (+/-) ± 1%
INSULATION SYSTEM Class H
PROTECTION IP23
RATED POWER FACTOR 0,8
WEIGHT COMP. ALTERNATOR (KG) 1202,5
Genset Controllers

Genset Controllers

Datakom d-700

Datakom D-700

ONE SOLUTION FOR ALL GENSET APPLICATIONS.

FEATURES

  • 128x64 graphical LCD display
  • Diesel and gas genset support
  • Supports up to 48 gensets
  • Automatic learning/self adjust
  • Direct governor & AVR control
  • Voltage and phase matching
  • kW & kVAr load sharing
  • Multiple topologies
  • 6xCT, true mains metering
  • True soft transferin both ways
  • Peak Lopping / peak shaving (mains or genset priority)
  • Mains de-coupling protection
  • R.O.C.O.F protection
  • Vector shift protection
  • Reversepower protection
  • Over/under freq. Protection
  • Over/under voltage protection
  • Smart load management
  • Smart genset sequencing
  • Run/stop priority support
  • Equal agingof gensets
  • Base load (power export)
  • Unmanaged distributed power export support
  • AVR & GOV droop support
  • Dead bus sensing
  • 400Hz operation support
  • 400 event logs, full snapshot
  • All parameters front panel editable
  • 3 level configuration password
  • Downloadable languages
  • Waveform display of V & I
  • Harmonic analysis of V & I
  • Synchroscope & check synch
  • 12 configurable digital inputs
  • Inputs expandable to 44
  • 8 configurable digital outputs
  • Outputs expandable to 38
  • 7 configurable analog inputs
  • Both CANBUS-J1939 & MPU
  • 3 configurable service alarms
  • Multiple automatic exerciser
  • Weekly operation schedule
  • Dual mutual standby with equal aging of gensets
  • Manual “speed fine adjust” on selected ECUs
  • Automatic fuel pump control
  • Disable protections feature
  • Excess power protection
  • Overload IDMT protection
  • Load shedding, dummy load
  • Multiple load management
  • Current unbalance protection
  • Voltage unbalance protection
  • Fuel filling & fuel theft alarms
  • Battery back-up real time clock
  • Idle speed control
  • Battery charge run enabled
  • Combat mode support
  • Multiple nominal conditions
  • Tactor & MCB drive
  • 4 quadrant genset power counters
  • Mains power counters
  • Fuel filling counter
  • Fuel consumption counter
  • Modem diagnostics display
  • Configurable through USB, RS-485 and GPRS
  • Free configuration program
  • Allows SMS controls
  • Ready for central monitoring
  • Mobile genset support
  • Automatic GSM geo-location
  • GPS connectivity (RS232)
  • Dynamic DNS support
  • Easy USB firmware upgrade
  • IP65 rating with standard gasket

MEASUREMENTS

  • Mains & genset PN/PP voltages
  • Mains & genset frequency
  • Mains & genset phase currents
  • Mains & genset neutral currents
  • Mains & genset, phase & total, kW, kVA, kVAr, pf
  • Engine speed
  • Battery voltage

COMMUNICATIONS

  • Ethernet (10/100Mb)
  • 4-band GPRS modem (optional)
  • USB Device
  • RS-485 (2400-115200baud)
  • RS-232 (2400-115200baud)
  • MicroSD card slot
  • J1939-CANBUS
  • Geo-locating through GSM
  • GPS support (RS-232)
  • Embedded web server
  • Web monitoring& programming
  • Internet Central Monitoring
  • SMS message sending
  • E-mail sending
  • Free PC software: Rainbow Plus
  • Modbus RTU
  • SNMP (with TRAP messages)
  • SNTP

FUNCTIONALITIES

  • Multi genset synch & load share
  • Mains synchronization
  • Single genset parallel with mains
  • AMF unit
  • ATS unit
  • Remote start controller
  • Manual start controller
  • Engine controller
  • Remote display panel
  • Internal battery (optional)
  • Remote display panel

GENSET CONTROLLERS FOR SYNCHRONIZATION SYSTEMS OPTIONAL

Next generation synchronizing genset controller capable of every communication and functionality.

DEEPSEA 8610 DEEPSEA 8620 DEEPSEA 8660 ComAp InteliGen BaseBox ComAp InteliGen 200
DEEPSEA 8610 DEEPSEA 8620 DEEPSEA 8660 ComAp InteliGen BaseBox ComAp InteliGen 200

Datakom D700 DEEPSEA 8610 DEEPSEA 8620 DEEPSEA 8660 ComAp InteliGen BaseBox ComAp InteliGen 200
Multi genset synch & load share
Mains synchronization
Single genset parallel with mains
ATS unit
Remote start controller
Manual start controller
Engine controller
Data logging
Remote display panel
Ethernet (10/100Mb) OPTIONAL
4-band GPRS modem OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL
USB Device
RS-485 (2400-115200baud)
RS-232 (2400-115200baud) OPTIONAL
MicroSD card slot
J1939-CANBUS OPTIONAL
Geo-locating through GSM OPTIONAL OPTIONAL OPTIONAL
Embedded web server
Web monitoring& programming
Internet Central Monitoring
SMS message sending
E-mail sending
Free PC software
Modbus RTU
SNMP
Configurable digital inputs 12 12 12 11 12 8
Configurable digital outputs 8 8 8 8 12 8
Configurable analog inputs 7 4 4 0 3 4
ETW DT EM 1100

Canopy

  • Modular type sound-proof canopy
  • Canopy installation executed with screw and nut, without welding process
  • Epoxy and polyester powder painted canopy
  • Weatherproof canopy rating is IP 23
  • Canopy designed for easy maintenance
  • Lockable doors on both sides of canopy
  • Emergency stop button
  • Transparent panel inspection window
  • Insulation details: Non-flammeable acoustic foam
  • Nano tech cleaning system
  • Container optional

ETW DT EM 1100
Dimensions Dimensions
(W x L x H) mm

N/A
Weight (Kg) Weight (Kg)
N/A
Fuel tank capacity (lt) Fuel tank capacity (lt)
2082

SILENCER OPTIONS

  • Standard industrial type
  • Critical type
  • Hospital type

CANOPY OPTIONS

  • Standard canopy
  • Super silent canopy
  • Extra süper silent canoy (thicker insulation)

GEN-SET SAFETY PROTECTION & ALARMS

  • High water temperature
  • Low oil pressure
  • High & low engine speed
  • Low radiator water level
  • Over current load
  • High & low genset voltage
  • Start/stop failure

OPTIONAL EQUIPMENTS

  • Charge ammeter
  • Moulded case circuit braker (in automatic models)
  • Hospital/Critical type silencer
  • Modular type sound-proof canopy
  • Mobile - trailer
  • Synchronization control panel for 2-16 gensets
  • 3 pole/4 pole automatic transfer panel (A.T.S.)
  • Fuel and oil heater
  • Alternator heater
  • Automatic fuel filling system
  • Fuel-water seperator filter
  • PMG warning system
Copyright © 2022 EMSA Generator. All rights reserved.
EMSA JeneratörEMSA Jeneratör