1540 kVA DCC Diesel Generator Set QSK50G4 S7L1D-C

1540 kVA CUMMINS QSK50G4, STAMFORD S7L1D-C, 50hz 3phase Diesel Generator Set - E CM ST 1700 (2)

{PAGENO}
certifications
Emsa reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice.
E CM ST 1700 (2)
EMSA Generator - PHP first page
E CM ST 1700 (2)
CUMMINS Series
Diesel Generator Sets
STANDBY
kVA
1700
kW
1360
DCCP
kVA
1540
kW
1232

 

1700 kVA CUMMINS QSK50G4, STAMFORD S7L1D-C, 50 hz
Water Cooled
Water Cooled
50 hz
50 hz
Easy maintenance
Easy maintenance
Modular type sound-proof canopy
Modular type sound-proof canopy
3 phase
3 phase
Diesel
Diesel
Warning system for decreasing fuel with electronic fuel level sender
Warning system for decreasing fuel with electronic fuel level sender
Remote control system
Remote control system

Emergency Standby Power: Emergency standby power, provided by diesel generators, acts as a backup during power outages. These generators kick in swiftly during emergencies, ensuring continuity for critical operations. Ideal for homes, businesses, and industries, their usage duration should be limited to prevent wear. Strict standards like NFPA 110 ensure their reliability.

Data Center Continuous Power : Data center continuous power is defined as being the maximum power which a generating set is capable of delivering while supplying a variable or continuous electrical load and during unlimited run hours, meet the Uptime Institute Tier III and IV requirements as detaled in the Uptime Institute Tier Standarts:Topology. The power ratings , given above have been identified according to conditions of 100kPa barometric pressure (110m. altitude), 25°C ambient temperature.

 

QUALITY STANDARDS

Our generators are manufactured in compliance with TS ISO 8528-4, TS ISO 8528-5, TS ISO 8528-13, with CE Declaration.

EMSA Has ISO 9001-2015, ISO 14001-2015, ISO 45001-2018, ISO 27001, ISO 27701 and ISO 1002-2006 management system certificates from Kiwa, an accredited independent quality organization.

Engine Specifications

Engine Specifications

  • CUMMINS series heavy duty diesel engine
  • 4 CYCLE, WATER COOLING SYSTEM, TURBOCHARGED - AFTERCOOLER INDUCTION
  • ECU governor system
  • 12/24 volt self-starter and charger alternator
  • Changeable air, fuel and oil filter
  • Flexible fuel pipe

 

  • Oil discharge valve and extention pipe
  • Industrial type silencer, exhaust spiral or compensator
  • Maintenance free battery
  • Engine block water heater
  • Diesel gen-set maintenance and operating instructions and electrical circuit diagram
MODEL
QSK50G4
POWER
STANDBY kW
1477
DCCP kW
1328
SPEED (rpm)
1500
CYCLE
4
DISPLACEMENT (lt)
50,3
NUMBER OF CYLINDERS
16V
BORE AND STROKE
159x159
COMPRESSION RATIO
15:01

 

GOVERNOR TYPE
ECU
INDUCTION
TURBOCHARGED - AFTERCOOLER
COMBUSTION SYSTEM
DIRECT
COOLING SYSTEM
WATER
FUEL CONSUMPTION (lt/h)
100% OF PRIME POWER
314
75% OF PRIME POWER
238
50% OF PRIME POWER
164
TOTAL LUBRICATION SYSTEM CAPACITY (lt)
234,7
TOTAL COOLANT CAPACITY (lt)
294
Alternator Specifications

Alternator Specifications

  • Brushless, single bearing, flexible disc 4 poles alternator for harmonic failure
  • H type isolation class
  • IP 23 protection class
  • Self exciter

 

  • Electronic automatic voltage regulator
  • Stator 2/3 step for harmonic failure
  • The alternator windings are protected by insulating varnish against oil and acid
BRAND
STAMFORD
MODEL
S7L1D-C
FREQUENCY (HZ)
50
POWER (KVA)
1660
DESIGN
4 pole, brushless
CONNECTION TYPE
Star
VOLTAGE (V)
400

 

phase
3
A.V.R.
MX341
VOLTAGE REGULATION (+/-)
± 1%
INSULATION SYSTEM
Class H
PROTECTION
IP23
RATED POWER FACTOR
0,8
WEIGHT COMP. ALTERNATOR (KG)
3020

Note: Alternator DCCP rating according to class H, Standby rating is according to 163/27 °C

Genset Controllers

Genset Controllers

dse 8610

DEEPSEA 8610

DEEPSEA 8610 is a diesel gen-set control unit for common paralleling applications supporting both single and multiple gen-sets running in grid-tied or island operations.

E CM ST 1700 (2)

Container

  • Chassis parts and load-bearing construction are manufactured from 140mm NPU
  • The base metal sheet is manufactured from 2/3 diamond-shaped metal sheet
  • Sidewall metal sheets are manufactured from 1.5mm ST 37 DKP trapezoidal metal sheet
  • The top metal sheet will be manufactured from 1.5mm ST 37 DKP trapezoidal metal sheet
  • Air disposing and suction parts are manufactured with the normal shutter in bolt-mounted hot-plug
  • Lifting lugs are manufactured to bear the total load of the container (with generator)(8 pcs ISO Locked)
  • PPG RAL 9010 paint application is followed for painting

 

  • Internal illumination has 2x1x18 Watt waterproof fixture and 1x1x16 A monophasic plug fitting
  • Top wall isolation is 0.8mm galvanised perforated metal sheet coating on 8cm fibro-glass glass wool plate
  • The double-winged main door is manufactured with a pipe-type locking mechanism
  • Service doors are manufactured with 4 single-winged and internal panic bar mechanisms to be locked outside (These doors are designed mounted inside the container body and doorknobs do not exceed container body
  • Emergency stop button on long edges
  • Warning signs are placed to necessary places inside and outside the container

 
E CM ST 1700 (2)
 
1700 kVA CUMMINS QSK50G4, STAMFORD S7L1D-C, 50 hz
Dimensions
(W x L x H) mm
xx
1700 kVA CUMMINS QSK50G4, STAMFORD S7L1D-C, 50 hz
Weight (Kg)
1700 kVA CUMMINS QSK50G4, STAMFORD S7L1D-C, 50 hz
Fuel tank capacity (lt)

Internal type
 
E CM ST 1700 (2)
 
1700 kVA CUMMINS QSK50G4, STAMFORD S7L1D-C, 50 hz
Dimensions
(W x L x H) mm
xx
1700 kVA CUMMINS QSK50G4, STAMFORD S7L1D-C, 50 hz
Weight (Kg)
1700 kVA CUMMINS QSK50G4, STAMFORD S7L1D-C, 50 hz
Fuel tank capacity (lt)

Internal type
1700 kVA CUMMINS QSK50G4, STAMFORD S7L1D-C, 50 hz
Internal type

SILENCER OPTIONS

  • Standard industrial type
  • Critical type
  • Hospital type

 

CONTAINER OPTIONS

  • Standard container
  • Acoustic container

GEN-SET SAFETY PROTECTION & ALARMS

  • High water temperature
  • Low oil pressure
  • High & low engine speed
  • Low radiator water level

 

  • Over current load
  • High & low genset voltage
  • Start/stop failure

OPTIONAL EQUIPMENTS

  • Charge ammeter
  • Moulded case circuit braker (in automatic models)
  • Hospital/Critical type silencer
  • Modular type sound-proof canopy
  • Mobile - trailer
  • Synchronization control panel for 2-16 gensets

 

  • 3 pole/4 pole automatic transfer panel (A.T.S.)
  • Fuel and oil heater
  • Alternator heater
  • Automatic fuel filling system
  • Fuel-water seperator filter
  • PMG warning system