2250 kVA DCC Diesel Generator Set QSK60-G6 S7L1D-J

2250 kVA CUMMINS QSK60-G6, STAMFORD S7L1D-J, 60hz 3phase Diesel Generator Set - E CM ST 2500/6

{PAGENO}
certifications
Emsa reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice.
E CM ST 2500/6
EMSA Generator - PHP first page
E CM ST 2500/6
CUMMINS Series
Diesel Generator Sets
STANDBY
kVA
2500
kW
2000
DCC
kVA
2250
kW
1800
Data tolerance ±5%

 

Water Cooled
Water Cooled
60 hz
60 hz
Easy maintenance
Easy maintenance
3 phase
3 phase
Diesel
Diesel
Warning system for decreasing fuel with electronic fuel level sender
Warning system for decreasing fuel with electronic fuel level sender
Remote control system
Remote control system

Emergency Standby Power: Emergency standby power, provided by diesel generators, acts as a backup during power outages. These generators kick in swiftly during emergencies, ensuring continuity for critical operations. Ideal for homes, businesses, and industries, their usage duration should be limited to prevent wear. Strict standards like NFPA 110 ensure their reliability.

Data Center Continuous : Data center power is defined as being the maximum power which a generating set is capable of delivering while supplying a variable or continuous electrical load and during unlimited run hours, meet the Uptime Institute Tier III and IV requirements as detaled in the Uptime Institute Tier Standarts:Topology. The power ratings , given above have been identified according to conditions of 100kPa barometric pressure (110m. altitude), 25°C ambient temperature.

 

QUALITY STANDARDS

Our generators are manufactured in compliance with TS ISO 8528-4, TS ISO 8528-5, TS ISO 8528-13, with CE Declaration.

EMSA Has ISO 9001-2015, ISO 14001-2015, ISO 45001-2018, ISO 27001, ISO 27701 and ISO 1002-2006 management system certificates from Kiwa, an accredited independent quality organization.

Engine Specifications

Engine Specifications

  • CUMMINS series heavy duty diesel engine
  • 4 CYCLE, WATER COOLING SYSTEM, TURBOCHARGED - AFTERCOOLER INDUCTION
  • Electronic governor system
  • 24 volt self-starter and charger alternator
  • Changeable air, fuel and oil filter
  • Flexible fuel pipe

 

  • Oil discharge valve and extention pipe
  • Industrial type silencer, exhaust spiral or compensator
  • Maintenance free battery
  • Engine block water heater
  • Diesel gen-set maintenance and operating instructions and electrical circuit diagram
MODEL
QSK60-G6
POWER
STANDBY kW
2179
DCC kW
1975
SPEED (rpm)
1800
CYCLE
4
DISPLACEMENT (lt)
60
NUMBER OF CYLINDERS
16 V
BORE AND STROKE
159 x 190
COMPRESSION RATIO
14,5 : 1

 

GOVERNOR TYPE
Electronic
INDUCTION
TURBOCHARGED - AFTERCOOLER
COMBUSTION SYSTEM
DIRECT
COOLING SYSTEM
WATER
FUEL CONSUMPTION (lt/h)
100% OF PRIME POWER
466
75% OF PRIME POWER
356
50% OF PRIME POWER
247
TOTAL LUBRICATION SYSTEM CAPACITY (lt)
280
TOTAL COOLANT CAPACITY (lt)
490
Alternator Specifications

Alternator Specifications

  • Brushless, single bearing, flexible disc 4 poles alternator for harmonic failure
  • H type isolation class
  • IP 23 protection class
  • Self exciter

 

  • Electronic automatic voltage regulator
  • Stator 2/3 step for harmonic failure
  • The alternator windings are protected by insulating varnish against oil and acid
BRAND
STAMFORD
MODEL
S7L1D-J
FREQUENCY (HZ)
60
POWER (KVA)
2500
DESIGN
4 pole, brushless
CONNECTION TYPE
Star
VOLTAGE (V)
400

 

phase
3
A.V.R.
MX322
VOLTAGE REGULATION (+/-)
± 0,5%
INSULATION SYSTEM
Class H
PROTECTION
IP23
RATED POWER FACTOR
0.8
WEIGHT COMP. ALTERNATOR (KG)
4515
Genset Controllers

Genset Controllers

InteliGen4 200

ComAp InteliGen4 200

InteliGen4 200 is a diesel gen-set control unit for common paralleling applications supporting both single and multiple gen-sets running in grid-tied or island operations.

Functions and protections

Support of functions and protections as defined by ANSI (American National Standards Institute)

Description ANSI code Description ANSI code
Master unit 1 Incomplete sequence relay 48
Stopping device 5 Temperature monitoring 49T
Multi-function device 11 Overcurrent 50/50TD
Overspeed 12 Earth fault 50G
Underspeed 14 Breaker failure 50BF
Speed and frequency matching device 15 Overcurrent IDMT 51
Data communication device 16 AC circuit breaker 52
Starting-to-running transition contactor 19 Power factor 55
Synchronizing check 25 Overvoltage 59
Thermal relay 26 Aux Overvoltage 59X
Undervoltage 27 Pressure switch 63
Aux Battery Under Voltage 27X Liquid level switch 71
Overload (real power) 32P Alarm relay** 74
Reverse power 32R Vector shift 78
Master sequence device 34 Reclosing relay 79
Undercurrent 37 Overfrequency 81O
Excitation loss 40 Underfrequency 81U
Unit sequence starting* 44 ROCOF 81R
Current unbalance 46 Auto selective control/transfer 83
Voltage unbalance / Negative sequence voltage 47 Regulating device 90

*MINT ** extension module IGL-RA15 required

Certifications and standards

arrow EN 61000-6-2 arrow EN 60068-2-6 (2÷25 Hz / ±1,6 mm; 25÷100 Hz / 4.0 g) ul
eac
eac
eac
arrow EN 61000-6-4 arrow EN 60068-2-27 (a=500 m/s² ; T=6 ms)
arrow EN 61010-1 arrow EN 60068-2-30:2005 25/55°C, RH 95%, 48hours
arrow EN 60068-2-1 (-20 °C/16 h) arrow EN 60529 (front panel IP65, back side IP20)
arrow EN 60068-2-2 (70 °C/16 h) arrow UL 6200

|

 
E CM ST 2500/6
 
Dimensions
(W x L x H) mm
2360x6150x3247
Weight (Kg)
Fuel tank capacity (lt)
3000
External type

SILENCER OPTIONS

  • Standard industrial type
  • Critical type
  • Hospital type

 

CANOPY OPTIONS

  • Standard canopy
  • Super silent canopy
  • Extra super silent canopy (thicker insulation)

GEN-SET SAFETY PROTECTION & ALARMS

  • High water temperature
  • Low oil pressure
  • High & low engine speed
  • Low radiator water level

 

  • Over current load
  • High & low genset voltage
  • Start/stop failure

OPTIONAL EQUIPMENTS

  • Charge ammeter
  • Moulded case circuit braker (in automatic models)
  • Hospital/Critical type silencer
  • Modular type sound-proof canopy
  • Mobile - trailer
  • Synchronization control panel for 2-16 gensets

 

  • 3 pole/4 pole automatic transfer panel (A.T.S.)
  • Fuel and oil heater
  • Alternator heater
  • Automatic fuel filling system
  • Fuel-water seperator filter
  • PMG warning system