1500 kVA Diesel Generator Set - E PR ST 1500

1500 kVA PERKINS 4012-46TWG3A, STAMFORD S6L1D-H4, 50hz 3phase Diesel Generator Set - E PR ST 1500

PDF
{PAGENO}
Emsa reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice.
E PR ST 1500
EMSA Generator - PHP first page
E PR ST 1500
PERKINS Series
Diesel Generator Sets
STAND BY
kVA
1500
kW
1200
PRIME
kVA
1350
kW
1080

 

1500 kVA PERKINS 4012-46TWG3A, STAMFORD S6L1D-H4, 50 hz
Water Cooled
Water Cooled
50 hz
50 hz
Easy maintenance
Easy maintenance
Modular type sound-proof canopy
Modular type sound-proof canopy
3 phase
3 phase
Diesel
Diesel
Warning system for decreasing fuel with electronic fuel level sender
Warning system for decreasing fuel with electronic fuel level sender
Remote control system
Remote control system

Standby Rating for a standby engine should be sized for a maximum of 70% average load factor and roughly 200 hours per year. Stand­by power ratings should never be applied except in true emergency outage situations. With standby rated generators there is no overload capability built into the units.

Prime Power is the maximum power accessible at the variable load for an unlimited number of hours per year in a variable load setting. It is not advisable that the variable load exceed 70% average of the prime power rating during any operational period. If the engine is run­ning at 100% prime power, yearly hours should not exceed 500. Overload situations should be avoided however a 10% overload capability is available for a 1 hour period within a 12 hour cycle of operation.

Continuous Power is used in applications where suppliying power is at a constant 100% load for an unlimited number of hours each year. Continuous power rated units are most widely used in applications where the power grid is unreachable.

 

QUALITY STANDARDS

Our generators are manufactured in compliance with VDE 0530, BSE 4999 BS5000, IEC 34, EN12601; EN60204-1; TS ISO 8528-1 … -13; EN12100-1; EN12100-2; EN61000-6-4; EN61000-6-2; EN61000-4-11; EN61000-4-6; EN61000-4-5; EN61000-4-2; EN55011; EN55016-2-1; EN55016-2-3; EN61000-3-2; EN61000-3-3; EN55014-1; EN61000-6-2; EN61000-4-3; EN61000-4-4; EN61000-4-8; EN61000-4-11; TS EN ISO 3744; TS EN ISO 3746; TS EN 60034-1; TS EN 60034-22; TS EN ISO 3046; BS 5514; NEMA MG 21; IEC 60034, BS 4999/5000 and TS EN 60947-1..4 standards.

We have ISO 9001-2015, ISO 14001-2015, ISO 45001-2018 and ISO 1002-2006 management system certificates from Kiwa, an accredited independent quality organization.

Our generators up to 400 kw are manufactured in compliance with 2000/14/EC European noise emission directive and certified from Ente Certificazione Macchine.

We also have TS ISO 8528-4, TS ISO 8528-5, TS EN 13501-1+A1:2013 flame retardancy and TTS EN ISO 9227 certificates against anti-corrosion together with CE Declaration.

Engine Specifications

Engine Specifications

  • PERKINS series heavy duty diesel engine
  • 4 CYCLE, WATER COOLING SYSTEM, TURBOCHARGED - INTERCOOLER INDUCTION
  • Electronic governor system
  • 12/24 volt self-starter and charger alternator
  • Changeable air, fuel and oil filter
  • Flexible fuel pipe

 

  • Oil discharge valve and extention pipe
  • Industrial type silencer, exhaust spiral or compensator
  • Maintenance free battery
  • Engine block water heater (in automatic models)
  • Diesel gen-set maintenance and operating instructions and electrical circuit diagram
MODEL
4012-46TWG3A
POWER
STAND BY kW
1263
PRIME kW
1149
SPEED (rpm)
1500
CYCLE
4
DISPLACEMENT (lt)
45,842
NUMBER OF CYLINDERS
12 - 60° V
BORE AND STROKE
160 x 190
COMPRESSION RATIO
13 : 1

 

GOVERNOR TYPE
Electronic
INDUCTION
TURBOCHARGED - INTERCOOLER
COMBUSTION SYSTEM
DIRECT
COOLING SYSTEM
WATER
FUEL CONSUMPTION (lt/h)
100% OF PRIME POWER
283
75% OF PRIME POWER
213
50% OF PRIME POWER
151
TOTAL LUBRICATION SYSTEM CAPACITY (lt)
177
TOTAL COOLANT CAPACITY (lt)
201
Alternator Specifications

Alternator Specifications

  • Brushless, single bearing, flexible disc 4 poles alternator for harmonic failure
  • H type isolation class
  • IP 21-23 protection class
  • Self exciter

 

  • Electronic automatic voltage regulator
  • Stator 2/3 step for harmonic failure
  • The alternator windings are protected by insulating varnish against oil and acid
BRAND
STAMFORD
MODEL
S6L1D-H4
FREQUENCY (HZ)
50
POWER (KVA)
1500
DESIGN
4 pole, brushless
CONNECTION TYPE
Star
VOLTAGE (V)
400

 

phase
3
A.V.R.
MX341
VOLTAGE REGULATION (+/-)
± 1%
INSULATION SYSTEM
Class H
PROTECTION
IP23
RATED POWER FACTOR
0,8
WEIGHT COMP. ALTERNATOR (KG)
2760
Genset Controllers

Genset Controllers

Datakom Smart 500-mk2

Datakom SMART 500-MK2

The SMART 500-MK2 is a cost effective genset controller ready for BMS integration and internet monitoring

 

OPTIONAL GENSET CONTROLLERS OPTIONAL

Datakom SMART 200

Datakom 200

Datakom D500

Datakom D500

Datakom D500-GSM

Datakom D500-GSM

DEEPSEA 6120

DEEPSEA 6120

DEEPSEA 7320

DEEPSEA 7320

ComAp AMF25

ComAp AMF25

 

 
Datakom SMART 200
Datakom SMART 500-MK2
Datakom D500
Datakom D500 GSM
DEEPSEA 6120
DEEPSEA 7320
ComAp AMF25
AUTOMATIC MAINS MONITORING
MANUEL START
REMOTE START
REMOTE MONITORING WITH SIM CARD
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
1 ADITIONAL OPTION (HORN, OIL-FUEL HEATER ETC.)
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
LIGHT WARNING AND MIMIC DIAGRAM
BATTERY CHARGER
RS-485 COMMUNICATION
OPTIONAL
OPTIONAL
OPTIONAL
ETHERNET (TCP-IP) COMMUNICATION
OPTIONAL
OPTIONAL

 

GENSET CONTROLLERS FOR SYNCHRONIZATION SYSTEMS OPTIONAL

Next generation synchronizing genset controller capable of every communication and functionality.

DEEPSEA 8610

DEEPSEA 8610

DEEPSEA 8620

DEEPSEA 8620

DEEPSEA 8660

DEEPSEA 8660

ComAp InteliGen BaseBox

ComAp InteliGen BaseBox

ComAp InteliGen 200

ComAp InteliGen 200
E PR ST 1500

Container

  • Chassis parts and load-bearing construction are manufactured from 140mm NPU
  • The base metal sheet is manufactured from 2/3 diamond-shaped metal sheet
  • Sidewall metal sheets are manufactured from 1.5mm ST 37 DKP trapezoidal metal sheet
  • The top metal sheet will be manufactured from 1.5mm ST 37 DKP trapezoidal metal sheet
  • Air disposing and suction parts are manufactured with the normal shutter in bolt-mounted hot-plug
  • Lifting lugs are manufactured to bear the total load of the container (with generator)(8 pcs ISO Locked)
  • PPG RAL 9010 paint application is followed for painting

 

  • Internal illumination has 2x1x18 Watt waterproof fixture and 1x1x16 A monophasic plug fitting
  • Top wall isolation is 0.8mm galvanised perforated metal sheet coating on 8cm fibro-glass glass wool plate
  • The double-winged main door is manufactured with a pipe-type locking mechanism
  • Service doors are manufactured with 4 single-winged and internal panic bar mechanisms to be locked outside (These doors are designed mounted inside the container body and doorknobs do not exceed container body
  • Emergency stop button on long edges
  • Warning signs are placed to necessary places inside and outside the container
  • -

 
E PR ST 1500
 
1500 kVA PERKINS 4012-46TWG3A, STAMFORD S6L1D-H4, 50 hz
Dimensions
(W x L x H) mm
2280x6750x3322 *
1500 kVA PERKINS 4012-46TWG3A, STAMFORD S6L1D-H4, 50 hz
Weight (Kg)
13146
1500 kVA PERKINS 4012-46TWG3A, STAMFORD S6L1D-H4, 50 hz
Fuel tank capacity (lt)
3000
External type
 
E PR ST 1500
 
1500 kVA PERKINS 4012-46TWG3A, STAMFORD S6L1D-H4, 50 hz
Dimensions
(W x L x H) mm
2200x4950x2720
1500 kVA PERKINS 4012-46TWG3A, STAMFORD S6L1D-H4, 50 hz
Weight (Kg)
11058
1500 kVA PERKINS 4012-46TWG3A, STAMFORD S6L1D-H4, 50 hz
Fuel tank capacity (lt)
3000
External type
1500 kVA PERKINS 4012-46TWG3A, STAMFORD S6L1D-H4, 50 hz
External type

SILENCER OPTIONS

  • Standard industrial type
  • Critical type
  • Hospital type

 

CONTAINER OPTIONS

  • Standard container
  • Acoustic container

GEN-SET SAFETY PROTECTION & ALARMS

  • High water temperature
  • Low oil pressure
  • High & low engine speed
  • Low radiator water level

 

  • Over current load
  • High & low genset voltage
  • Start/stop failure

OPTIONAL EQUIPMENTS

  • Charge ammeter
  • Moulded case circuit braker (in automatic models)
  • Hospital/Critical type silencer
  • Modular type sound-proof canopy
  • Mobile - trailer
  • Synchronization control panel for 2-16 gensets

 

  • 3 pole/4 pole automatic transfer panel (A.T.S.)
  • Fuel and oil heater
  • Alternator heater
  • Automatic fuel filling system
  • Fuel-water seperator filter
  • PMG warning system

Stay updated with EMSA